L&T-Sargent & Lundy Limited
About Us
Overview
CSR
Policies and Frameworks
Management
Awards
Sectors
Thermal
Renewable
Transmission & Distribution
Water Treatment
Sustainable Solutions
Services
Detail Engineering
Owner's Engineering
Independent / Lender's Engineering
Project Management Services
Special Engineering Services
Investors
Technical Papers
Careers
News & Stories
Contact Us
News & Stories
Contact Us
  • L&T-S&L
  • Sectors
  • Water Treatment
  • 2x660 MW NTPC Khargone Ultra Supercritical Power Plant, Madhya Pradesh, India

Related Links

  • Water Treatment
About Us
Overview
CSR
Policies and Frameworks
Management
Awards
Sectors
Thermal
Renewable
Transmission & Distribution
Water Treatment
Sustainable Solutions
Services
Detail Engineering
Owner's Engineering
Independent / Lender's Engineering
Project Management Services
Special Engineering Services
Contact Us

Registered Office

L&T House
Ballard Estate P.O. Box 278 
Mumbai - 400 001 
Maharashtra, India   

Tel No.: +91-22-6752 5656 
Fax: +91-22-6752 5858 

Investors
Annual Reports
Technical Papers
Careers

Follow Us

  • Copyright & Terms
  • Privacy Policy

© 2026 L&T-Sargent & Lundy Limited. All rights reserved.

WATER TREATMENTWATER TREATMENT

2x660 MW NTPC Khargone Ultra Supercritical Power Plant
Madhya Pradesh, India

Name of Project : 2x660 MW NTPC Khargone Ultra Super Critical Power Plant, MP, India

Owner : NTPC Ltd, India

Client : Larsen & Toubro Limited, India

Capacity : 2x660 MW (Ultra Supercritical)

L&T-S&L’s scope : Complete Basic and Detail engineering for the entire EPC of the project

Configuration :

  • Two (2) L&T-MHPS make Boilers with side mill arrangement
  • Two (2) L&T-MHPS make Steam Turbine Generators (STGs)

Key Technical Features :

  • Supercritical, Single Reheat, Once through, Balance Draft, PF Fired Boilers with vertical water walls and internal rifle tubes simpler in construction having lower pressure drop. Furnace designed for lower slag deposition and lower NOx fuel firing system
  • STG of capacity 660 MW (270 kg/cm²(a) / 600°C configuration) each consists of one HP, one IP and two (2) LP cylinders, tandem – compound quadruple exhaust, condensing reheat turbine designed for high operating efficiency and maximum reliability
  • STG auxiliaries like Boiler Feed Pumps (BFP), Condensate Extraction Pump (CEP), Condensate Polishing Unit, LP Heater Drain Pump, DM cooling water pumps, Vacuum pumps, heat-exchangers etc.
  • Deaerator, LP Heaters (5 Nos.) & Double Train of HP Heaters (3 Nos.) with Topping Desuperheater
  • Dual pressure once through type Condensers having divided water box
  • Metallic casing type cooling water pumps
  • Two (2) Induced Draft Cooling Tower
  • 275 m High twin flue chimney.
  • Solar Panels on the roof of selected buildings
  • Complete Balance of Plant viz. Raw water intake system, HVAC system, firefighting system, fuel oil system, ash handling system, coal handling system, water treatment system, Cooling water system, Effluent treatment system, compressed air, mill reject system, Gas-chlorination, tanks, hydrogen generation plant etc.

Fuel : Blended coal (Indian and Imported coal in ratio of 70:30)

Year of commissioning : 2019